CC-GDF System (“Scavenger” No. 1 Direct Waste Liquid Filtration System) | Patented Product
CC-GDF System (“Scavenger” No. 1 Direct Waste Liquid Filtration System) | Patented Product
CC-GDF System (“Scavenger” No. 1 Direct Waste Liquid Filtration System) | Patented Product
CC-GDF System (“Scavenger” No. 1 Direct Waste Liquid Filtration System) | Patented Product
CC-GDF System (“Scavenger” No. 1 Direct Waste Liquid Filtration System) | Patented Product
+
  • CC-GDF System (“Scavenger” No. 1 Direct Waste Liquid Filtration System) | Patented Product
  • CC-GDF System (“Scavenger” No. 1 Direct Waste Liquid Filtration System) | Patented Product
  • CC-GDF System (“Scavenger” No. 1 Direct Waste Liquid Filtration System) | Patented Product
  • CC-GDF System (“Scavenger” No. 1 Direct Waste Liquid Filtration System) | Patented Product
  • CC-GDF System (“Scavenger” No. 1 Direct Waste Liquid Filtration System) | Patented Product
  • Product Description
  • Technical Application Analysis

    Waste leachate and kitchen wastewater share the following characteristics: high suspended solids (SS), high chemical oxygen demand (COD), high oil content, and significant fluctuations in water quality and quantity. Conventional pretreatment processes, such as air flotation and sedimentation, often suffer from large land footprint, high energy consumption, substantial chemical sludge production, and poor resilience to shock loads.

    The Application Value of CC-GDF

    1. Counteracting high suspended solids and colloids: 
    · Coagulation: By dosing coagulants and flocculants, fine suspended particles, colloids, certain oils and fats, and emulsified organic matter in the wastewater are efficiently “captured” and aggregated into dense flocs, thereby creating the necessary conditions for subsequent direct filtration. 
    · 3-Free direct filtration: Serving as a synergistic and enhanced coagulation unit, it directly traps these alum flocs and larger particulates.


    2. Addressing water quality fluctuations (with undifferentiated influent): 
    · This technology exhibits broad compatibility with influent water quality and can withstand the typical concentration shocks associated with landfill leachate and food-waste wastewater, thereby ensuring the stability of the pretreated effluent.


    3. Reduce the load on subsequent processing: 
    · By effectively removing suspended solids (removal rate > 95%) and a portion of chemical oxygen demand (removal rate > 50%), the load on subsequent biochemical treatment units (such as UASB and MBR) or advanced treatment units is significantly reduced, thereby enhancing the stability and efficiency of the entire water treatment system.


    4. Achieving low-cost operation of the pretreatment section: 
    · Power-free water production: Significant energy savings can be achieved by reducing electricity consumption in the pre-treatment stage, which is a major energy consumer. 
    · No secondary pollution: This approach eliminates the large volumes of chemical sludge generated by conventional coagulation and sedimentation, thereby reducing the high costs associated with sludge treatment and disposal as well as the associated environmental pressures.

    Equipment Selection and Specification Table (Secondary Direct Filtration)

    · Two-stage direct filtration design: The two-stage direct filtration design ensures a suspended solids (SS) removal rate of greater than 97%.

    · Robust, corrosion-resistant design: A carbon steel main structure, combined with specialized anti-corrosion treatment for parts in contact with water, ensures long-lasting durability of the equipment.

    · Efficient and energy-saving operation: Distinguishes between backwash mode (high power) and routine operation mode (low power), resulting in low actual energy consumption and cost-effective operation.

    · Flexible Custom Solutions: To meet the diverse needs of different projects, we offer customized services for non-standard water volumes.

CC-GDF System (“Scavenger” No. 1 Direct Waste Liquid Filtration System) | Patented Product

The “Scavenger” CC-GDF (Coagulation-Conditioning & Gravity Direct Filtration) high-concentration wastewater direct-filtration pretreatment system is primarily used for the pretreatment of highly concentrated, challenging wastewater, significantly simplifying the process, reducing costs, and minimizing secondary pollution. Application areas include: · Leachate from waste transfer stations/incinerators · Wastewater from food-waste treatment centers · Other pretreatment applications for high-suspended-solids, high-concentration organic wastewater


Keywords:


Share Now

  • Product Description
  • Technical Application Analysis

    Waste leachate and kitchen wastewater share the following characteristics: high suspended solids (SS), high chemical oxygen demand (COD), high oil content, and significant fluctuations in water quality and quantity. Conventional pretreatment processes, such as air flotation and sedimentation, often suffer from large land footprint, high energy consumption, substantial chemical sludge production, and poor resilience to shock loads.

    The Application Value of CC-GDF

    1. Counteracting high suspended solids and colloids: 
    · Coagulation: By dosing coagulants and flocculants, fine suspended particles, colloids, certain oils and fats, and emulsified organic matter in the wastewater are efficiently “captured” and aggregated into dense flocs, thereby creating the necessary conditions for subsequent direct filtration. 
    · 3-Free direct filtration: Serving as a synergistic and enhanced coagulation unit, it directly traps these alum flocs and larger particulates.


    2. Addressing water quality fluctuations (with undifferentiated influent): 
    · This technology exhibits broad compatibility with influent water quality and can withstand the typical concentration shocks associated with landfill leachate and food-waste wastewater, thereby ensuring the stability of the pretreated effluent.


    3. Reduce the load on subsequent processing: 
    · By effectively removing suspended solids (removal rate > 95%) and a portion of chemical oxygen demand (removal rate > 50%), the load on subsequent biochemical treatment units (such as UASB and MBR) or advanced treatment units is significantly reduced, thereby enhancing the stability and efficiency of the entire water treatment system.


    4. Achieving low-cost operation of the pretreatment section: 
    · Power-free water production: Significant energy savings can be achieved by reducing electricity consumption in the pre-treatment stage, which is a major energy consumer. 
    · No secondary pollution: This approach eliminates the large volumes of chemical sludge generated by conventional coagulation and sedimentation, thereby reducing the high costs associated with sludge treatment and disposal as well as the associated environmental pressures.

    Equipment Selection and Specification Table (Secondary Direct Filtration)

    · Two-stage direct filtration design: The two-stage direct filtration design ensures a suspended solids (SS) removal rate of greater than 97%.

    · Robust, corrosion-resistant design: A carbon steel main structure, combined with specialized anti-corrosion treatment for parts in contact with water, ensures long-lasting durability of the equipment.

    · Efficient and energy-saving operation: Distinguishes between backwash mode (high power) and routine operation mode (low power), resulting in low actual energy consumption and cost-effective operation.

    · Flexible Custom Solutions: To meet the diverse needs of different projects, we offer customized services for non-standard water volumes.

Please provide your phone number and email address, and we will contact you promptly within one business day to resolve your inquiry as soon as possible.

Self-flow suspended-particle-media biological filtration reactor (the “3-Free direct filtration technology): Application scenarios include post-biological treatment sludge–water separation (replacing secondary sedimentation tanks and MBR systems) and denitrification sludge–water separation. The self-flow suspended-particle-media biological filtration reactor is also known as a denitrification biological filtration reactor, commonly referred to as the “3-Free-No” direct filtration unit (Patent: ZL2018 20780799.4).
Learn more View More
The Mefit TUFBR™-S3F Direct Filtration Unit (also known as the “3-Free” Direct Filtration Unit) is a groundbreaking, integrated water treatment system. It combines physicochemical conditioning, sludge–water separation, and deep filtration into a single unit. Its core technology features a proprietary self-flowing suspended-particle-media sludge–water separation filter element paired with a dual-settling-zone design, seamlessly integrating the stability of conventional sedimentation tanks with the high efficiency of filtration equipment. Thanks to its unique flow-path design and intelligent recirculating cleaning technology, this system can directly and efficiently treat various types of high-turbidity surface water and complex industrial wastewater, while replacing air-flotation units, primary sedimentation tanks, and secondary sedimentation tanks in traditional systems.
Learn more View More
A New Paradigm for Rural and Township Wastewater Treatment: the AAO–Self‑Autotrophic Direct Filtration (AAO‑ADF) System This system deeply integrates the well‑established AAO biological treatment process with the revolutionary “self‑autotrophic direct filtration” unit, aiming to provide an efficient, stable, and virtually maintenance‑free distributed wastewater treatment solution for rural and township areas. Typical application scenarios include: – Domestic wastewater treatment in rural residential settlements and natural villages – Township communities, tourist towns, and clusters of guesthouses – Isolated facilities such as schools, military barracks, and highway service areas – Upgrading and expanding capacity of conventional wastewater treatment plants
Learn more View More
The TUFBR™-IFB Integrated Direct-Filtration Basin (Industrial Grade) is primarily used for the pretreatment of industrial wastewater. With its ultra-simplified operation and maintenance, extremely low costs, and exceptional adaptability, it transforms wastewater pretreatment from a traditional “passive acceptance” approach to a “proactive control” strategy, thereby laying a solid foundation at the source for the stable, efficient, and economical operation of the entire wastewater treatment system. Typical application scenarios include the pretreatment of various complex industrial wastewaters for SS reduction and oil removal, among other functions.
Learn more View More
< 1234 >